- Electrical Machines - Home
- Basic Concepts
- Electromechanical Energy Conversion
- Energy Stored in Magnetic Field
- Singly-Excited and Doubly Excited Systems
- Rotating Electrical Machines
- Electrical Machines Types
- Faraday’s Laws of Electromagnetic Induction
- Concept of Induced EMF
- Fleming's Left Hand and Right Hand Rules
- Transformers
- Electrical Transformer
- Construction of Transformer
- EMF Equation of Transformer
- Turns Ratio and Voltage Transformation Ratio
- Ideal Transformer
- Practical Transformer
- Ideal and Practical Transformers
- Transformer on DC
- Losses in a Transformer
- Efficiency of Transformer
- 3-Phase Transformer
- Types of Transformers
- More on Transformers
- Transformer Working Principle
- Single-Phase Transformer Working Principle
- 3-Phase Transformer Principle
- 3-Phase Induction Motor Torque-Slip
- 3-Phase Induction Motor Torque-Speed
- 3-Phase Transformer Harmonics
- Double-Star Connection (3-6 Phase)
- Double-delta Connection (3-6 Phase)
- Transformer Ratios
- Voltage Regulation
- Delta-Star Connection (3-Phase)
- Star-Delta Connection (3-Phase)
- Autotransformer Conversion
- Back-to-back Test (Sumpner's Test)
- Transformer Voltage Drop
- Autotransformer Output
- Open and Short Circuit Test
- 3-Phase Autotransformer
- Star-Star Connection
- 6-Phase Diametrical Connections
- Circuit Test (Three-Winding)
- Potential Transformer
- Transformers Parallel Operation
- Open Delta (V-V) Connection
- Autotransformer
- Current Transformer
- No-Load Current Wave
- Transformer Inrush Current
- Transformer Vector Groups
- 3 to 12-Phase Transformers
- Scott-T Transformer Connection
- Transformer kVA Rating
- Three-Winding Transformer
- Delta-Delta Connection Transformer
- Transformer DC Supply Issue
- Equivalent Circuit Transformer
- Simplified Equivalent Circuit of Transformer
- Transformer No-Load Condition
- Transformer Load Condition
- OTI WTI Transformer
- CVT Transformer
- Isolation vs Regular Transformer
- Dry vs Oil-Filled
- DC Machines
- Construction of DC Machines
- Types of DC Machines
- Working Principle of DC Generator
- EMF Equation of DC Generator
- Derivation of EMF Equation DC Generator
- Types of DC Generators
- Working Principle of DC Motor
- Back EMF in DC Motor
- Types of DC Motors
- Losses in DC Machines
- Applications of DC Machines
- More on DC Machines
- DC Generator
- DC Generator Armature Reaction
- DC Generator Commutator Action
- Stepper vs DC Motors
- DC Shunt Generators Critical Resistance
- DC Machines Commutation
- DC Motor Characteristics
- Synchronous Generator Working Principle
- DC Generator Characteristics
- DC Generator Demagnetizing & Cross-Magnetizing
- DC Motor Voltage & Power Equations
- DC Generator Efficiency
- Electric Breaking of DC Motors
- DC Motor Efficiency
- Four Quadrant Operation of DC Motors
- Open Circuit Characteristics of DC Generators
- Voltage Build-Up in Self-Excited DC Generators
- Types of Armature Winding in DC Machines
- Torque in DC Motors
- Swinburne’s Test of DC Machine
- Speed Control of DC Shunt Motor
- Speed Control of DC Series Motor
- DC Motor of Speed Regulation
- Hopkinson's Test
- Permanent Magnet DC Motor
- Permanent Magnet Stepper Motor
- DC Servo Motor Theory
- DC Series vs Shunt Motor
- BLDC Motor vs PMSM Motor
- Induction Motors
- Introduction to Induction Motor
- Single-Phase Induction Motor
- 3-Phase Induction Motor
- Construction of 3-Phase Induction Motor
- 3-Phase Induction Motor on Load
- Characteristics of 3-Phase Induction Motor
- Speed Regulation and Speed Control
- Methods of Starting 3-Phase Induction Motors
- More on Induction Motors
- 3-Phase Induction Motor Working Principle
- 3-Phase Induction Motor Rotor Parameters
- Double Cage Induction Motor Equivalent Circuit
- Induction Motor Equivalent Circuit Models
- Slip Ring vs Squirrel Cage Induction Motors
- Single-Cage vs Double-Cage Induction Motor
- Induction Motor Equivalent Circuits
- Induction Motor Crawling & Cogging
- Induction Motor Blocked Rotor Test
- Induction Motor Circle Diagram
- 3-Phase Induction Motors Applications
- 3-Phase Induction Motors Torque Ratios
- Induction Motors Power Flow Diagram & Losses
- Determining Induction Motor Efficiency
- Induction Motor Speed Control by Pole-Amplitude Modulation
- Induction Motor Inverted or Rotor Fed
- High Torque Cage Motors
- Double-Cage Induction Motor Torque-Slip Characteristics
- 3-Phase Induction Motors Starting Torque
- 3-phase Induction Motor - Rotor Resistance Starter
- 3-phase Induction Motor Running Torque
- 3-Phase Induction Motor - Rotating Magnetic Field
- Isolated Induction Generator
- Capacitor-Start Induction Motor
- Capacitor-Start Capacitor-Run Induction Motor
- Winding EMFs in 3-Phase Induction Motors
- Split-Phase Induction Motor
- Shaded Pole Induction Motor
- Repulsion-Start Induction-Run Motor
- Repulsion Induction Motor
- PSC Induction Motor
- Single-Phase Induction Motor Performance Analysis
- Linear Induction Motor
- Single-Phase Induction Motor Testing
- 3-Phase Induction Motor Fault Types
- Synchronous Machines
- Introduction to 3-Phase Synchronous Machines
- Construction of Synchronous Machine
- Working of 3-Phase Alternator
- Armature Reaction in Synchronous Machines
- Output Power of 3-Phase Alternator
- Losses and Efficiency of an Alternator
- Losses and Efficiency of 3-Phase Alternator
- Working of 3-Phase Synchronous Motor
- Equivalent Circuit and Power Factor of Synchronous Motor
- Power Developed by Synchronous Motor
- More on Synchronous Machines
- AC Motor Types
- Induction Generator (Asynchronous Generator)
- Synchronous Speed Slip of 3-Phase Induction Motor
- Armature Reaction in Alternator at Leading Power Factor
- Armature Reaction in Alternator at Lagging Power Factor
- Stationary Armature vs Rotating Field Alternator Advantages
- Synchronous Impedance Method for Voltage Regulation
- Saturated & Unsaturated Synchronous Reactance
- Synchronous Reactance & Impedance
- Significance of Short Circuit Ratio in Alternator
- Hunting Effect Alternator
- Hydrogen Cooling in Synchronous Generators
- Excitation System of Synchronous Machine
- Equivalent Circuit Phasor Diagram of Synchronous Generator
- EMF Equation of Synchronous Generator
- Cooling Methods for Synchronous Generators
- Assumptions in Synchronous Impedance Method
- Armature Reaction at Unity Power Factor
- Voltage Regulation of Alternator
- Synchronous Generator with Infinite Bus Operation
- Zero Power Factor of Synchronous Generator
- Short Circuit Ratio Calculation of Synchronous Machines
- Speed-Frequency Relationship in Alternator
- Pitch Factor in Alternator
- Max Reactive Power in Synchronous Generators
- Power Flow Equations for Synchronous Generator
- Potier Triangle for Voltage Regulation in Alternators
- Parallel Operation of Alternators
- Load Sharing in Parallel Alternators
- Slip Test on Synchronous Machine
- Constant Flux Linkage Theorem
- Blondel's Two Reaction Theory
- Synchronous Machine Oscillations
- Ampere Turn Method for Voltage Regulation
- Salient Pole Synchronous Machine Theory
- Synchronization by Synchroscope
- Synchronization by Synchronizing Lamp Method
- Sudden Short Circuit in 3-Phase Alternator
- Short Circuit Transient in Synchronous Machines
- Power-Angle of Salient Pole Machines
- Prime-Mover Governor Characteristics
- Power Input of Synchronous Generator
- Power Output of Synchronous Generator
- Power Developed by Salient Pole Motor
- Phasor Diagrams of Cylindrical Rotor Moto
- Synchronous Motor Excitation Voltage Determination
- Hunting Synchronous Motor
- Self-Starting Synchronous Motor
- Unidirectional Torque Production in Synchronous Motor
- Effect of Load Change on Synchronous Motor
- Field Excitation Effect on Synchronous Motor
- Output Power of Synchronous Motor
- Input Power of Synchronous Motor
- V Curves & Inverted V Curves of Synchronous Motor
- Torque in Synchronous Motor
- Construction of 3-Phase Synchronous Motor
- Synchronous Motor
- Synchronous Condenser
- Power Flow in Synchronous Motor
- Types of Faults in Alternator
- Miscellaneous Topics
- Electrical Generator
- Determining Electric Motor Load
- Solid State Motor Starters
- Characteristics of Single-Phase Motor
- Types of AC Generators
- Three-Point Starter
- Four-Point Starter
- Ward Leonard Speed Control Method
- Pole Changing Method
- Stator Voltage Control Method
- DOL Starter
- Star-Delta Starter
- Hysteresis Motor
- 2-Phase & 3-Phase AC Servo Motors
- Repulsion Motor
- Reluctance Motor
- Stepper Motor
- PCB Motor
- Single-Stack Variable Reluctance Stepper Motor
- Schrage Motor
- Hybrid Schrage Motor
- Multi-Stack Variable Reluctance Stepper Motor
- Universal Motor
- Step Angle in Stepper Motor
- Stepper Motor Torque-Pulse Rate Characteristics
- Distribution Factor
- Electrical Machines Basic Terms
- Synchronizing Torque Coefficient
- Synchronizing Power Coefficient
- Metadyne
- Motor Soft Starter
- CVT vs PT
- Metering CT vs Protection CT
- Stator and Rotor in Electrical Machines
- Electric Motor Winding
- Electric Motor
- Useful Resources
- Quick Guide
- Resources
- Discussion
Hopkinson's Test: How to Test the Efficiency of DC Machines?
Hopkinson's test is a method of testing the efficiency of DC machines. The Hopkinson's test is known as regenerative test or back-to-back test or heat-run test.
This test requires two identical shunt machines which are mechanically coupled and also connected electrically in parallel. One machine acts as a motor and the other as a generator.
The motor takes its input from the supply and the mechanical output of the motor drives the generator. The electrical output of the generator is used in supplying the input to the motor. Therefore, the output of each machine is fed as input to the other.
When both the machines are run at rated load, the input from the supply is equal to the total losses of both the machines. Thus, the power input form the supply is very small.
Connection Diagram
The connection diagram of Hopkinson's test is shown in the figure.

In the connection diagram, the machine M acts as a motor and is started from the supply with the help of starter. The switch S is kept open. The field current of the machine M is adjusted with the help of field rheostat Rm to make the motor to run at its rated speed. The machine G acts as a generator.
As the G is driven by the machine M, hence it runs at rated speed of M. The field current of the machine G is so adjusted with the help of its field rheostat Rgthat the armature voltage of the generator G is somewhat higher than the supply voltage. When the voltage of the generator is equal to and of the same polarity of the busbar voltage, the switch S is closed and the generator is connected to the busbar.
Now, both the machines are connected in parallel across the supply voltage. Under this condition, the generator neither taking any current from nor giving any current to the supply, thus it is said to be float. Now, by adjusting the excitation of the machines with the help of the field rheostats, any load can be thrown on the machines.
Here,
$$\mathrm{\text{Input power from the supply } \: = \: VI}$$
This input power from the supply is equal to the total losses of both the machines.
$$\mathrm{\text{Armature Cu loss of motor } \: = \: I_{am}^{2}R_{a}}$$
$$\mathrm{\text{field Cu loss of motor } \: = \: I_{shm}^{2}R_{shm}}$$
$$\mathrm{\text{Armature Cu loss of generator } \: = \: I_{ag}^{2}R_{a}}$$
$$\mathrm{\text{field Cu loss of generator } \: = \: I_{shg}^{2}R_{shg}}$$
As the two machines are identical, the constant losses of both the machines Pc are assumed to be equal and is given by,
$$\mathrm{P_{C} \: = \: \text{ (Power input from supply) - (Armature and shunt cu losses of both machines)}}$$
$$\mathrm{\Rightarrow \: P_{C} \: = \: VI \: - \: (I_{am}^{2}R_{a} \: + \: I_{shm}^{2}R_{shm} \: + \: I_{ag}^{2}R_{a} \: + \: I_{shg}^{2}R_{shg})}$$
It was assumed that the constant losses being equally divided between the two machines.
$$\mathrm{\therefore \: \text{ Constant loss per Machine } \: = \: \frac{P_{C}}{2}}$$
Now, the efficiency of two machines can be determined as follows −
Efficiency of Generator −
$$\mathrm{\text{Generator output } \: = \: VI_{ag}}$$
$$\mathrm{\text{Constant losses for generator } \: = \: \frac{P_{C}}{2}}$$
$$\mathrm{\text{Armature Cu loss of generator } \: = \: I_{ag}^{2}R_{a}}$$
$$\mathrm{\text{field Cu loss of generator } \: = \: I_{shg}^{2}R_{shg}}$$
Therefore, the efficiency of the generator is given by,
$$\mathrm{\eta_{g} \: = \: \frac{Output}{Output \: + \: Losses} \: = \: \frac{VI_{ag}}{VI_{ag} \: + \: I_{ag}^{2}R_{a} \: + \: I_{shg}^{2}R_{shg} \: + \: \frac{P_{C}}{2}}}$$
Efficiency of Motor
$$\mathrm{\text{Motor input } \: = \: VI_{m} \: = \: V(I_{am} \: + \: I_{shm})}$$
$$\mathrm{\text{Constant losses for motor} \: = \: \frac{P_{C}}{2}}$$
$$\mathrm{\text{Armature Cu loss of motor} \: = \: I_{am}^{2}R_{a}}$$
$$\mathrm{\text{field Cu loss of motor } \: = \: I_{shm}^{2}R_{shm}}$$
Therefore, the efficiency of the motor is given by,
$$\mathrm{\eta_{m} \: = \: \frac{Input \: - \: Losses}{Input}\: = \: \frac{[V(I_{am} \: + \: I_{shm})] \: - \: [I_{am}^{2}R_{a} \: + \: I_{shm}^{2}R_{shm} \: + \: \frac{P_{C}}{2}]}{V(I_{am} \: + \: I_{shm})}}$$
Advantages of Hopkinson's Test
The advantages of Hopkinson's test for determination of efficiency of DC machines are −
- This method is very economical as the power draw from the supply is very low.
- The commutation conditions and the temperature rise can be checked under rated load conditions.
- Efficiency at different loads can be determined.
- Large DC machines can be testing without wasting much amount of power.
- The stray losses are taken into account since both the machines being operated under rated load conditions.
Disadvantages of Hopkinson's Test
The main disadvantage of this test is the necessity of two practically identical DC machines to be available. As a result, this test is only suitable for manufacturer of large DC machines.